66 -- Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer

Notice Date
9/17/2026 1:27:30 PM
 
Notice Type
Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
DEPT OF COMMERCE NIST GAITHERSBURG MD 20899 USA
 
ZIP Code
20899
 
Solicitation Number
1333ND26QNB640601
 
Response Due
9/21/2026 9:00:00 AM
 
Archive Date
10/06/2026
 
Point of Contact
Rudolph Spencer
 
E-Mail Address
rudolph.spencer@nist.gov
(rudolph.spencer@nist.gov)
 
Small Business Set-Aside
SBA Small Business Set Aside - Total
 
Description
***Amendment 0001**** Amendment 0001 provides resposnes to questions received in response to the solicitation. Q.1. I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system? A.1. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 � 200) ppb. Q.2. What types of samples will be tested? A.2. This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases. Q.3. What specific substances or compounds need to be detected or analyzed in these samples? If available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly. A.3. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. For improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts. Q.4. Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)? A.4. The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel. There is not an extension to the solicitation as a result of this amendment. The question period for this soliciation will close today, September 17,2026, at 4:00 PM ET. End of Amendment 0001 ******** See attached.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/c3d1218425364835b7b429d402a51245/view)
 
Place of Performance
Address: Gaithersburg, MD 20899, USA
Zip Code: 20899
Country: USA
 
Record
SN07976014-F 20260919/260917230057 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

| FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.