SOLICITATION NOTICE

Y -- Fire suppression system installation

Notice Date
9/11/2026 12:00:00 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
MRPBS MINNEAPOLIS MN MINNEAPOLIS MN 55401 USA
 
ZIP Code
55401
 
Solicitation Number
12639526Q0210
 
Response Due
9/11/2026 10:00:00 AM
 
Archive Date
09/30/2026
 
Point of Contact
Jim Roloff
 
E-Mail Address
james.g.roloff@usda.gov
(james.g.roloff@usda.gov)
 
Small Business Set-Aside
SBA Small Business Set Aside - Total
 
Description
Due to a recent fire in building 6418 at Moore Air Base, Texas, a wet fire suppression system is needed. Building 6418 was constructed in the early 1980s with no fire suppression initially. Contractor shall provide design/as-built drawings submittals and installation of a new retrofitted system. The system shall be a turnkey project encompassing everything needed to have a fully functioning fire suppression system. Solicitation documents are posted below. NOTE: For those wishing to attend the site visit, please send names of attendees to james.g.roloff@usda,gov. A valid drivers license or state ID is required. Amendment 1 is posted below. RFI: Does Building 6418 currently have an existing fire alarm panel/system that the sprinkler monitoring would tie into? If so, could you please provide the panel/system type, make/model, or any available details needed for a sprinkler monitoring quote? The fire panels are old and obsolete. They will be replaced at another time, but the new sprinkler system must be able to connect to a fire panel in the future. No monitoring is needed. The sign-in sheet for the site visit is posted below. Building drawings posted below. RFIs and responses posted below. Amendment 2 is posted below. It extends the closing date. Amendment 3 is posted below. It extends the closing date. Additional RFIs and responses posted below. Amendment 4 is posted below. There's a change to the response to RFI 6 posted here on August 17. The correct answer is as follows: 6) Please confirm if a CVPC/PEX fire suppression would be sufficient or the USDA prefers schedule 10 or schedule 40 Victaulic black iron piping? Or provide a specification with minimum standards for Moore Airfield that must be met regarding fire suppression piping? It is typical for local building codes and state codes to be of a lesser standard than what a federal installation requires. The statement of work indicates in accordance state and local codes and standards only opening the door for a CVPC system to be priced. The USDA prefers the use of Schedule 40 Victaulic black iron piping. An amendment to postpone this solicitation indefinitely is posed below.
 
Web Link
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/6f9f00eb7c744d4e9075f8043bba5f5e/view)
 
Place of Performance
Address: Edinburg, TX 78541, USA
Zip Code: 78541
Country: USA
 
Record
SN07967434-F 20260913/260911230048 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

| FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2026, Loren Data Corp.