SOLICITATION NOTICE
J -- Repair of Water Storage Tank Leaking Seams at the Northampton VA Medical Center
- Notice Date
- 9/10/2026 12:00:00 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 332420
— Metal Tank (Heavy Gauge) Manufacturing
- Contracting Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
- ZIP Code
- 04330
- Solicitation Number
- 36C24126Q0820
- Response Due
- 9/17/2026 9:00:00 AM
- Archive Date
- 10/02/2026
- Point of Contact
- Yolanda Rankin
- E-Mail Address
-
yolanda.rankin@va.gov
(yolanda.rankin@va.gov)
- Small Business Set-Aside
- SBA Small Business Set Aside - Total
- Description
- Amendment No.: 0001 Solicitation No.: 36C24126Q0820 Date: September 10, 2026 Purpose of Amendment The purpose of this amendment is to provide responses to questions submitted regarding the solicitation. As a result of these questions and responses, the response date will remain unchanged. 1. Question: Please provide the tank capacity, leak locations, and severity details for the water storage tank repair. Answer: See the name plate in the appendix (Attachment) for all data. The tank capacity is 265,016 gallons. 2. Question: Tank Capacity: How many gallons does the tank hold? For reference, our records indicate various systems in this area ranging from 125 to 1,000 gallons. Answer: See the PWS in the Solicitation. There are at least two leaks noted on the upper and lower third of the tank. The bidder is responsible for adhering to the PWS. The VA does not anticipate the repair team requiring more than one to two days from the exterior to correct. 3. Question: Leak Location: Where on the tank are the leaking seams located? - Additional Details: Any further information regarding the severity or nature of the leaks. Answer: The contractor is responsible for determining where the leaking seams are located. The lowest seam leak produces a spurting stream, while the higher seam(s) produce drips. The leaks are not readily characterized beyond this observation. This repair must be assessed and repaired only by an OEM?authorized servicer. The seam leaks must be repaired from the exterior using OEM?approved materials, with authorized repairers using products such as those attached to spoon?feed them.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/workspace/contract/opp/8e2f129fd9944a23a8158fb13e1f9439/view)
- Place of Performance
- Address: Leeds, MA 01053, USA
- Zip Code: 01053
- Country: USA
- Zip Code: 01053
- Record
- SN07965062-F 20260912/260910230042 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |