SOURCES SOUGHT
65 -- Smoke Evacuators and Electrosurgical Generators | Tulsa VAMC
- Notice Date
- 7/3/2025 9:37:30 AM
- Notice Type
- Sources Sought
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- RPO WEST (36C24W) MCCLELLAN CA 95652 USA
- ZIP Code
- 95652
- Solicitation Number
- 36C24W25Q0273
- Response Due
- 7/10/2025 4:00:00 PM
- Archive Date
- 09/08/2025
- Point of Contact
- Bernadette Flores, Contract Specialist, Phone: 909-910-6732
- E-Mail Address
-
Bernadette.Flores@va.gov
(Bernadette.Flores@va.gov)
- Awardee
- null
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY The purpose of this Sources Sought is to conduct market research to procure Brand Name Only Medtronic AEX Generators, Medtronic Valleylab FT10 w/Universal Generator Carts, and Medtronic RapidVac Smoke Evacuators. This notice serves to survey the market to ascertain whether-or-not sources are capable of providing the requested supplies. You also must be an Authorized Distributor for Medtronic. This notice also allows potential contractors/vendors to submit a non-binding statement of interest and documentation demonstrating their capability. Please review the DRAFT Statement of Work (SOW) to compare your supply/service to what is requested. Complete the line-items below and submit any documentation supporting your product/service for consideration. Regional Procurement Office (RPO) - West is requesting responses from qualified business concerns; the qualifying NAICS code for this effort is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing. The Small Business Administration (SBA) Size Standard for this request is 1,250 Employees. This Sources Sought is to gain knowledge of potential qualified sources and their size classification(s) (Service Disabled/Veteran Owned Small Business (SD/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, or large business) relative to NAICS 334510. Responses to this notice, will be used by the Government to make appropriate acquisition decisions. After review of the responses to this notice, a solicitation announcement may be published. Responses to this notice are not considered adequate responses to any corresponding solicitation announcement. All interested offerors are requested to respond to this notice but are required to respond to the official solicitation announcement in order to be awarded the contract. INSTRUCTIONS: RESPONSES MUST INCLUDE THE FOLLOWING INFORMATION: Primary Information: Company Name Point of Contact (POC) Name Email Address Phone Number Unique Entity ID No. listed in the System of Awards Management (SAM) Business Size: (Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Small Business Other, Small Business, or Large Business) for the NAICS code 334510. IMPORTANT If your firm is a Socio-economic Small Business (SDVOSB, VOSB, Hub zone, 8(a), Small, Small disadvantaged, Woman owned small business), please state if your firm is a Nonmanufacturer under the Nonmanufacturer Rule. For more information about the Nonmanufacturer Rule and how it applies to your firm, click on this Small Business Administration link: https://www.sba.gov/partners/contracting-officials/small-business-procurement/nonmanufa cturer-rule Please check the lines below that apply to your firm: a. ____ Business size does not exceed 500 employees. b. ____ Firm is primarily engaged in the retail or wholesale trade and normally sells the type of products being supplied. c. ____ Firm takes ownership or possession of the item(s) with its personnel, equipment, or facilities in a manner consistent with industry practice. d. ____ Supplies the end products of a small business manufacturer or processor made in the United States. If a future solicitation requires the Buy American Statute, the following two clauses will apply: 52.225-1 Buy American-Supplies 52.225-2 Buy American Certificate Please indicate whether you hold a GSA Federal-Supply-Schedule or Indefinite Delivery/Indefinitely Quantity (IDIQ) contract that covers this type of request. If so, please provide the Schedule contract number. Must have an Authorized Distributor Letter issued from the manufacturer if not the manufacturer. Please specify place of manufacture. The attached SOW is a draft and is NOT finalized. If any portions are unclear, prohibited, and/or you are unsure about the draft description of the requirement please list your comments and/or concerns in your response so they can be addressed. Response is due by 07/10/2025, at 4:00 PM Pacific Time. Please submit e-mail responses to Bernadette Flores, Contract Specialist, at email address: Bernadette.Flores@va.gov. Please place Smoke Evacuators & Electrosurgical Generators in the subject line of your email. This notice is to assist the Department of Veterans Affairs in determining qualified sources only. CRITICAL MINIMUM REQUIREMENTS Medtronic AEX Generator with PlasmaBlades Soft tissue dissection device that uses brief, precise pulses of radiofrequency (RF) energy to cut and coagulate soft tissue. Unit will be capable of being utilized for General, Plastic and Reconstruction, ENT, Gynecologic, Orthopedic, Arthroscopic, Spinal and Neurological procedures. b. System will include: i. Generator will include: touchscreen interface, four (4) memory settings, must be lightweight with rapid startup and priming. ii. Plasma Blades: All plasma blades will include ergonomic handles. 3.0S Blade 4.0 Blade iii. Manuals: Two (2) copies each maintenance and operator manuals. c. Power Requirements: 120V, 60Hz d. Quantity: 2 Electrosurgical units - Valleylab FT10 w/Universal Generator Cart a. Dual output electrosurgical unit. Solid state power source with foot switch jacks, monopolar and bipolar outputs, and four independent modes of operation. b. Used in the operating room or surgicenter as an alternative to the scalpel for cutting tissue. c. Must be capable of an average sealing/fusion cycle time of 1 4 seconds.5, LigaSure devices to minimize thermal spread to surrounding tissue. d. Must be a plug-and-play system with automatic device detection and power setting. e. System should be an isolated output with natural convection and fan for cooling. f. Unit will include the following connector terminals: 1 standard monopolar with UFP, 1 advanced monopolar, 1 bipolar, and 1 LigaSure /bipolar receptacle. g. Unit must be capable of operating a duty cycle of 25%, defined as 10 seconds active and 30 seconds inactive, in any mode for a period of 4 hours. h. Unit must include: ethernet connection, bipolar cable compensation, touch screen and ES (soft coag) settings. i. Must include Universal Generator Cart: Constructed of aluminum with insulated nylon casters. j. Must include: i. Cautery Pencil Reference: E2516- 1 box of 50 ii. Grounding Pad Reference: E7507 - 1 box of 50 iii. Cautery Pencil with Smoke Evacuation Tubing Reference: CVLP2000 - 1 box of 20 iv. 10' Smoke Evacuation Tubing Reference: E3810 - 1 box of 20 v. Ligasure Small Jaw Open Sealer/Divider Reference: LF1212A - 1 Case of 6 vi. Ligasure Impact Curved, Large Jaw, Sealer/Divider Nano-Coated Reference: LF4418 - 1 Case of 6 vii. Ligasure Blunt Tip Sealer/Divider Nano-Coated Reference: LF1837 - 1 Case of 6 viii. Bipolar Forceps Reusable Cord Reference: E0020V - 1 box of 1 ix. Monopolar Reusable Cord (Laporoscopic) Reference: AB5005 - 1 box of 1 k. Power Requirements: 120V, 60Hz l. Quantity: 4 Medtronic RapidVac Smoke Evacuator a. Filtration system used in conjunction with laser operations to remove surgical laser plume. The unit includes a pneumatic foot switch, disposable 0.12 micron HEPA primary filters, a secondary 0.12 micron ULPA/carbon filter, disposable funnels, reducer fittings and connector hoses. b. This unit must be fully compatible with ESU and in no way negate the ESU or associated components warranties. c. Evacuator Dimensions: i. 8 high x 14 wide x 18 ¾ deep ii. 20.3 cm high x 35.5 cm wide x 47.6 cm deep d. Weight: 20 pounds (9 kg) e. ULPA Filter Efficiency: The ULPA filter is 99.9995% efficient on a 0.12 m particle size, but it can capture smaller and larger particles at equal or greater efficiency. f. Voltage operating range: 100-132 VAC, 50/60 Hz; current: 10 amps, maximum g. Certifications and Markings: UL, CE, cUL h. Quantity: 5 These devices must be compatible with the following accessories and must not negate warranty of equipment: IMF: 2694 Description: Cautery Pencil Reference: E2516 IMF: 4424 Description: Grounding Pad Reference: E7507 IMF: 21829 Description: Cautery Pencil with Smoke Evacuation Tubing Reference: CVLA2000 IMF: 17987 Description: Smoke Evacuation Tubing Reference: USUSEA3710 IMF: 5792 Description: Small Ligasure Reference: LF1212A IMF: 16968 Description: Large Ligasure Reference: LF4418 IMF: 17443 Description: Laparoscopic Ligasure Reference: LF1837 IMF: 17934 Description: Bi-Polar Reusable Cord Reference: E0020V IMF: 20157 Description: Mono-Polar Reusable Cord (Laparoscopic) Reference: 26006M IMF: 26018 Description: TUR Mono-Polar Reusable Cord 8mm Plug Reference: 277KB SPECIFICATIONS (including SALIENT CHARACTERISTICS) Contractor must provide products that meet or exceed the specifications in this table. BRAND NAME ONLY for the items listed below. QTY Unit of Issue Model Numbers are from Medtronic brands Item Description 2 EA 40-405-1 AEX Generator 2 EA PS210-030S PlasmaBlade 3.0S 2 EA PS200-040 PlasmaBlade 4.0 4 EA VLFT10GEN Valleylab FT 10 Electrosurgical Unit 4 EA VLFCRT Universal Generator Cart 4 EA E6008 Footswitch Standard 4 EA E6009 FOOTSWITCH, STANDARD BIPOLAR 1 CS E2516 Cautery Pencil Reference 1 BX E7507 Grounding Pad Reference box of 50 1 BX CVLP2000 Cautery Pencil with Smoke Evacuation Tubing box of 20 1 BX E3810 10' Smoke Evacuation Tubing box of 20 1 BX LF1212A Ligasure Small Jaw Open Sealer/Divider case of 6 6 BX LF4418 Ligasure Impact Curved, Large Jaw, Sealer/Divider Nano-Coated case of 6 6 BX LF1837 Ligasure Blunt Tip Sealer/Divider Nano-Coated 1 EA E0020V Bipolar Forceps Reusable Cord box of 1 1 EA AB5005 Monopolar Reusable Cord (Laparoscopic) box of 1 5 EA SE3690 RapidVac Smoke Evacuator 10 EA SEA3700 RapidVac ULPA filter 5 EA SEA3730 RapidVac interlink cable 5 EA SEA3745 RapidVac footswitch NOTES: Issuance of this notice does not constitute any obligation whatsoever on the part of the Government to procure these supplies and/or services, or to issue a solicitation, nor to notify respondents of the results of this notice. No solicitation documents exists at this time; however, in the event the acquisition strategy demonstrates that GSA is a viable option for procuring a solution, the RFQ shall be posted to GSA eBuy where only those firms who currently hold a GSA Schedule with the applicable SIN will be able to respond. The Department of Veterans Affairs is neither seeking quotes nor accepting unsolicited quotes, and responses to this notice cannot be accepted as offers. Any information the vendor considers proprietary should be clearly marked as such. The U.S. Government will not pay for any information or administrative costs incurred in response to this Sources Sought notice.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/ea212785c10f4c1f80d4a762acf609a0/view)
- Place of Performance
- Address: Jack C Montgomery VAMC 1101 Honors Heights Drive, Muskogee, OK 74401, USA
- Zip Code: 74401
- Country: USA
- Zip Code: 74401
- Record
- SN07499254-F 20250705/250703230042 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |