SOLICITATION NOTICE
61 -- 30 CES - Pad Mount Transformers (2 of 2)
- Notice Date
- 5/19/2025 7:13:46 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 335311
— Power, Distribution, and Specialty Transformer Manufacturing
- Contracting Office
- FA4610 30 CONS PK VANDENBERG SFB CA 93437-5212 USA
- ZIP Code
- 93437-5212
- Solicitation Number
- FA461025Q0034
- Response Due
- 5/30/2025 1:00:00 PM
- Archive Date
- 06/14/2025
- Point of Contact
- Greg Caresio, TSgt Mark Wheeler
- E-Mail Address
-
gregory.caresio.1@spaceforce.mil, mark.wheeler.10@spaceforce.mil
(gregory.caresio.1@spaceforce.mil, mark.wheeler.10@spaceforce.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- **Reason for updated solicitation: UPDATED pricing sheet** Five (5) phase pad-mounted transformers shall have the following voltage ratings: �112.5 KVA, 208Y/120, 12 kV �150 KVA, 480Y/277, 12 kV �300 KVA, 480Y/277, 12 kV �500 KVA, 480Y/277, 12.47 kV �750 KVA, 480Y/277, 12 kV In addition, the five phase pad-mounted transformers shall meet VSFB electrical requirements below: �All stainless-steel construction (includes tank, cabinet, base, radiators, fasteners, hinges, etc.),stainless-steel grade shall be 304L or 316L (if available). �""Pentahead"" cabinet locking mechanism/device. �Dead-Front construction (HV-200A load break elbows with shield adapters). �Externally clamped LV bushings with threaded copper stud for full load current below 2,100.amperes - NEMA spades shall be provided per ANSI hole requirements. �Radial feed or Loop feed �Frequency: 60Hz. �Windings: HV/LV copper �Mineral Oil-filled (Non-PCB): Type FR-3 Fluid. �Standard impedance. �Mild steel high-voltage/low-voltage compartment barriers. �Cooling fins. �Proper grounding provisions. �Dial type gauges for oil temperature, liquid level and pressure/vacuum. �Bay-O-Net fuses & current-limiting fuses: properly sized - additionally, the transformer shouldbe equipped with three spare fuses. �Two-position ""ON/OFF"" load break primary switch �5-position tap changer: (-5%, -2 � %, 0, +2 � %, +5%) �Automatic pressure relief device mounted on the terminal compartment. �Oil drain valve with sampling device, and an oil-fill/oil-level plug. �Nameplate and NEMA safety labels: include a ""UL Listed"" symbol on ratings label andnameplate. �Compliant with 2016 DOE Efficiency Standard. �Four (4) lifting lugs. �Entire exterior of the pad-mount transformer and terminal components shall be painted with aMunsell-Green, outdoor color-finish. �Guaranteed to have an average coil winding temperature of 65�C rise over an average ambient airtemperature of 30�C when operated at rated voltage and load conditions. �Provide DGA test to verify conformance to performance requirements as outlined in the latestrevisions of ANSI C57.12.00 and ANSI C57.12.90.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/1aaf7f7ea37c4fe49af0222053c8b2f7/view)
- Place of Performance
- Address: Lompoc, CA 93437, USA
- Zip Code: 93437
- Country: USA
- Zip Code: 93437