Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 21, 2025 SAM #8577
SOLICITATION NOTICE

61 -- 30 CES - Pad Mount Transformers (2 of 2)

Notice Date
5/19/2025 7:13:46 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
FA4610 30 CONS PK VANDENBERG SFB CA 93437-5212 USA
 
ZIP Code
93437-5212
 
Solicitation Number
FA461025Q0034
 
Response Due
5/30/2025 1:00:00 PM
 
Archive Date
06/14/2025
 
Point of Contact
Greg Caresio, TSgt Mark Wheeler
 
E-Mail Address
gregory.caresio.1@spaceforce.mil, mark.wheeler.10@spaceforce.mil
(gregory.caresio.1@spaceforce.mil, mark.wheeler.10@spaceforce.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
**Reason for updated solicitation: UPDATED pricing sheet** Five (5) phase pad-mounted transformers shall have the following voltage ratings: �112.5 KVA, 208Y/120, 12 kV �150 KVA, 480Y/277, 12 kV �300 KVA, 480Y/277, 12 kV �500 KVA, 480Y/277, 12.47 kV �750 KVA, 480Y/277, 12 kV In addition, the five phase pad-mounted transformers shall meet VSFB electrical requirements below: �All stainless-steel construction (includes tank, cabinet, base, radiators, fasteners, hinges, etc.),stainless-steel grade shall be 304L or 316L (if available). �""Pentahead"" cabinet locking mechanism/device. �Dead-Front construction (HV-200A load break elbows with shield adapters). �Externally clamped LV bushings with threaded copper stud for full load current below 2,100.amperes - NEMA spades shall be provided per ANSI hole requirements. �Radial feed or Loop feed �Frequency: 60Hz. �Windings: HV/LV copper �Mineral Oil-filled (Non-PCB): Type FR-3 Fluid. �Standard impedance. �Mild steel high-voltage/low-voltage compartment barriers. �Cooling fins. �Proper grounding provisions. �Dial type gauges for oil temperature, liquid level and pressure/vacuum. �Bay-O-Net fuses & current-limiting fuses: properly sized - additionally, the transformer shouldbe equipped with three spare fuses. �Two-position ""ON/OFF"" load break primary switch �5-position tap changer: (-5%, -2 � %, 0, +2 � %, +5%) �Automatic pressure relief device mounted on the terminal compartment. �Oil drain valve with sampling device, and an oil-fill/oil-level plug. �Nameplate and NEMA safety labels: include a ""UL Listed"" symbol on ratings label andnameplate. �Compliant with 2016 DOE Efficiency Standard. �Four (4) lifting lugs. �Entire exterior of the pad-mount transformer and terminal components shall be painted with aMunsell-Green, outdoor color-finish. �Guaranteed to have an average coil winding temperature of 65�C rise over an average ambient airtemperature of 30�C when operated at rated voltage and load conditions. �Provide DGA test to verify conformance to performance requirements as outlined in the latestrevisions of ANSI C57.12.00 and ANSI C57.12.90.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/1aaf7f7ea37c4fe49af0222053c8b2f7/view)
 
Place of Performance
Address: Lompoc, CA 93437, USA
Zip Code: 93437
Country: USA
 
Record
SN07448095-F 20250521/250519230044 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.