SOURCES SOUGHT
99 -- Brand Name - Supervisory Control And Data Acquisition (SCADA) system
- Notice Date
- 4/4/2025 2:31:21 PM
- Notice Type
- Sources Sought
- NAICS
- 237990
— Other Heavy and Civil Engineering Construction
- Contracting Office
- W074 ENDIST JACKSNVLLE JACKSONVILLE FL 32207-0019 USA
- ZIP Code
- 32207-0019
- Solicitation Number
- W912EP25X161X
- Response Due
- 5/2/2025 11:00:00 AM
- Archive Date
- 05/17/2025
- Point of Contact
- Chad Manson, Phone: 9042323420, Anelis NAZARIO CASTILLO, Phone: 9042323285
- E-Mail Address
-
chad.d.manson@usace.army.mil, anelis.i.nazario-castillo@usace.army.mil
(chad.d.manson@usace.army.mil, anelis.i.nazario-castillo@usace.army.mil)
- Description
- Sources Sought Synopsis W912EP25X161X Central Everglades Planning Project (CEPP) Contract 11C, EAA A-2 Reservoir Seepage Pump Station S-636, Palm Beach County, Florida This announcement is to notify industry about the Government�s intent to incorporate a brand name product requirement in an upcoming construction project. The product is the Supervisory Control and Data Acquisition (SCADA) system. This product is being considered to be included in the specifications to build a seepage pump station. This announcement seeks information from industry and will only be used for preliminary planning purposes. THIS IS NOT A SOLICITATION FOR OFFERS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. Respondents will not be notified of the results of the evaluation. The United States Army Corps of Engineers, Jacksonville District (SAJ) intends to include the following proprietary items in a solicitation for a construction acquisition under authority of FAR 6.302-1(c)(1), only one responsible source and no other supplies or services will satisfy agency requirements. This project may include a Brand Name only component, as described below, unless the results of this sources sought notification indicates otherwise. This notification serves three purposes: (1) to notify potential Offerors of the Government's intent to solicit a brand name only component under a future construction project; (2) to identify potential sources that can provide the brand name only item and/or equivalent; (3) notification of USACE�s intent to contract sole source for a Brand Name Only, if the market is unable to provide 'equivalent' products. In the event no equivalent equipment exists, the Brand Name Only justification will be issued pursuant to FAR Part 6.302-1(c)(1), ""Only One Responsible Source and no other supplies or services will satisfy agency requirements"". A subsequent market survey will not be published in support of a Justification and Approval (J&A) for sole sourcing the resultant product(s) or system(s) in the event an equivalent product is not submitted for consideration. In such instances, the brand name or equal component will be embedded in the construction project that will be issued/solicited competitively. Only that part of the project requiring brand name components will be sole source if no sources are able to prove an equal product. The SAJ has a portfolio of ongoing ecological programs in South Florida to include CEPP. These projects include hundreds of structures, pump stations, levees, and canals to control water movement throughout the area. All the elements are being tied, electronically, into the existing network of structures operated by the South Florida Water Management District (SFWMD). The system must operate consistently with other project features to maintain and/or improve existing levels of flood protection while enhancing environmental benefits to the system as a whole. The SFWMD Central Control System is a large, highly specialized system, which has been specifically designed for the unique requirements of remote operation of environmental restoration and flood control structures. It is required to operate reliably under all weather conditions, specifically during severe storm events when travel is extremely hazardous. The system may be considered to be a life safety critical system, in that it has a direct impact on the life safety of individuals living within the SFWMD area during a storm event due to the ability to control flooding by operation of the various gates and pumps. This is a new contract for the Central Everglades Planning Project (CEPP) Contract 11C, Everglades Agricultural Area (EAA) A-2 Reservoir Seepage Pump Station S-636. The project is part of the Comprehensive Everglades Restoration Plan (CERP) with the objective to improve the quantity, quality, timing, and distribution of water flows to the central Everglades, Water Conservation Area 3 (WCA-3) and Everglades National Park (ENP). The lead federal agency is the U.S. Army Corps of Engineers, Jacksonville District and the South Florida Water Management District (SFWMD) is the local non-Federal sponsor for the project. As a requirement of the project, the contractor will be responsible for purchasing and installing a Supervisory Control and Data Acquisition (SCADA) System as part of the S-636 pump station, which consists of brand-name products. The purpose of the Central Everglades Planning Project (CEPP) Everglades Agricultural Area (EAA) Reservoir Phase is to construct a 240,000-acre-foot EAA reservoir and 6,500 acre-foot stormwater treatment area, and integrate with A-1 FEB operations. The S-636 (CNT11C) Project is designed to perform two primary functions: � Return seepage lost from the A-2 Reservoir to the C-623 (Inflow-Outflow canal) � Manage and maintain the C-636 (Seepage Canal) within an authorized range. Project Description: The work includes transportation of fill material, construction of cofferdams, dewatering, excavation, construction of a new pumping station structure, construction of a box culvert integrated with the pumping station, and incidental related work. The new pumping station (S-636) structure has a pumping capacity of 250 CFS that consists of two 50 CFS, and two 75 CFS electric motor driven pumps. The station will include a backup generator to ensure continuous operation of the station in the event of commercial power interruption. The new pumping station is required to be constructed in dry conditions and will include installation of a cofferdam system. Installation of mechanical, electrical, and telecommunication systems are incidental to the construction of the pumping station. The SCADA system include the following major components; incidental items supporting the installation of these major components are shown indented just below the major component: Remote Terminal Unit Gated Culvert: Equipment Name Manufacturer Fire Alarm Control Panel - Honeywel Converter - Honeywell Security Alarm Control Panel - Honeywell APC Smart-Ups - APC Transceiver, Aprisa SR+, UHF, Half-Duplex - 4RF, USA Transceiver, Aprisa SR+, VHF, Half-Duplex - 4RF, USA Controller, 6A, 12VDC, Solar, Charger - Morningstar Cable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys. Connector, Coaxial, N-Male, Straight Plug, Lmr-400, Site Specific - Times Microwave Sys. Protector, Coaxial, Flange Mounted, DC Blocked, N-Female / N-Female - Polyphaser Radio Modem, Integra-Tr, Site Specific VHF/UHF - CalAmp Cable, Coaxial, Hybrid, Jumper, N-Male To SMA-Male, Rf Testing @ CF - Pasternack Cable, Serial, Hybrid, Rs-232 Motorola to Radio, Rj-45 To Db-9 Male, Non-Standard - Graybar Base Model, RTU, ACE3600, 12V Ps, CPU 3610, Basic Frame - Motorola Frame Option, RTU, ACE3600, 3 I/O Slots - Motorola I/O Module, RTU, ACE3600, 32 Di Fast 24V - Motorola I/O Module, RTU, ACE3600, 16 Do Ee Relay 2A - Motorola Power Supply, RTU, ACE3600, Dc Power Supply 18-72V - Motorola CPU, RTU, ACE3600, 3640, Upgrade - Motorola I/O Module, RTU, ACE3600, 8Ai +/-20 Ma - Motorola Plug-In, RTU, ACE3600, RS-232 - Motorola HMI Control Panel - Allen-Bradle, Motorola Cable, Coaxial, Flexible, Low Loss, Solid Core - Times Microwave Sys. Connector, Coaxial, N-Male, Right Angle, Lmr-400 - Times Microwave Sys. L-Foot, Solar Panel Rail, W/T-Bolt, Mill - Unirac Panel, 345 Watt, Solar - Mission Solar Energy Rail, Solar Panel Racking 168-Inch, Clear - Unirac Connector, Gnd, Lay-In, 4-14, #10, Tin - ILSCO/REXEL Nut, Hex, 3/8-16, 18-8 SS, 9/16 Acrflt - McMaster-Carr Nut, Hex, Ext Toothed Lk 1/4-20, 18-8 SS - McMaster-Carr Nut, Hex, Ext Toothed Lk 10-32, 18-8 SS - McMaster-Carr Plate, Backing, 2-13/16"" C-C Spacing - Sterling Industry Screw, Hex Hd, 1/4-20 X .75, 18-8 SS - McMaster-Carr Screw, Hex Hd, 3/8-16 X .3, 18-8 SS - McMaster-Carr Screw, Hex Hd, Serflg,10-32 X .75, 18-8 - McMaster-Carr Spar, Left, Vert, Solar Panel Bracket - Sterling Industry Spar, Right, Vert, Solar Panel Bracket - Sterling Industry U-Bolt,3/8-16, 2-7/16 Id, Galv. Steel - McMaster-Carr Washer, Flat,1/4, 18-8 SS - McMaster-Carr Washer, Split, 3/8, 18-8 SS - McMaster-Carr Weldment, Triangle, Solar Panel Bracket - Sterling Industry Core Mount SS Davit Sleeve DBI/Sala Model #8510110 - DBI/SALA Core Mount SS Davit Sleeve DBI/Sala Cap Model #8510827 - DBI/SALA Ladder Tie D-Bolt Anchorage Connector Model 417SS - MILLER Hilti Hit-Re 500 V3 With 3/4"" Has [304 316] 53/4"" Embedment - HILTI Face Mount SS Davit Sleeve DBI/Sala Model #8518348 - DBI/SALA Stainless Mini Rotary Latch Right Hand - EBERHARD Gate Hinge Assembly Self Closing - D&D Technologies Amphenol 90� Connector - Amphenol 3/8""-16 Pem Nut-SS Installed in the Side of Enclosure - PEM 1/4"" - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM 1/2"" - 20 Pem Nut - SS Pressed In - From Bottom Face - PEM Aluminum 1/4"" Thick Hinge - McMaster-Carr Test Kit for Measuring Chloride, Sulfate and Nitrate Ions on Steel and Coated Surfaces - CHLOR*RID International Inc. Test Kit for Identifying Amine Blush on Epoxy Surfaces - Elcometer Four Pin Disk Tumbler Lock - Illinois Lock Company Horn - Federal Signal Corporation 4A969 Weatherproof Box - Federal Signal Corporation Anti-Seize - Bostik 1/8 To 1/2 Hp, Single-Phase, 60 Cycle, 120 VAC, Integral Gear Motor - Sumitomo Chatsworth Universal Rack W/ Base Insulators - Chatsworth 120VAC Rackmount Power Strip - APC Fiber Optic Inside Plant Patch Panel - Corning Scada Switch - Cisco Scada Switch Wire Management - Chatsworth Scada Patch Panel 24 Port - Siemon Enterprise Switch - Cisco SCADA Patch Panel - Siemon KVM Rack Mount Console - Tripp Lite Server 6TB - Salient CCTV Switch - Fortinet CCTV TVSS - DITEK It System Ups - APC Ess System Ups - APC Single Mode Fiber Optic Patch Panel - Corning 24 Pair. - Corning Solara #20033-2, 20033-9, 20033-10 - Solara Digital Shaft Encoder - Design Analysis Associates Mounted Pump Cutoff Switches - Jerguson Ultrasonic Level Sensors - Drexelbrook Lightning/Surge: Power Supply Line Noise Suppressing Isolation Transformers and Surge Suppressors. - Edco Lightning/Surge Protection: Analog - Edco Norton Utilities - Norton One (1) Dell Timbuk2 16"" Carry Case - Dell Aircable Wireless Serial Connector - Aircable ATI's Mobility� Radeon� Hd3670 - 512Mb - ATI Dell Latitude E6410At6 Or Latest Version - Dell Microsoft Office (Latest Version) - Microsoft Dell Wireless 370 Bluetooth Module (2-1 + EDR) - Dell Rockwell Software's RSLogix5000 (Newest Version). - Rockwell Software Pro Soft Modbus Master/Slave Communications Interface Module for Control Logix - Pro Soft Allen-Bradley Stratix 5700 - Allen-Bradley Allen-Bradley Pv1900 PanelView +7 Series B Developed to Run on Windows 10 IOT Core. - Allen-Bradley Allen-Bradley PanelView Plus - Allen-Bradley Hoffman Consolet - Hoffman Capwap Software - Pile Dynamics, Inc. Testing Equipment - Pile Dynamics, Inc. The O-Rings on a Quick Disconnect - Chemours Simplex Compact Fuel Port - Simplex Pump Bearings - Thordon Shaft Couplings - Aquamet Shafts - Aquamet Shaft Bearing or Packing Box Sleeves - Aquamet Epoxy Coating - Chesterton 625kW Tier 4, Diesel Generator - Power Secure Submission Instructions: Any vendor wishing to provide a system(s) that is compatible with the existing equipment to be considered by the Government as described above must provide a copy of its brochure and any other capability statements/ datano later than May 2, 2025 at 2:00PM, EST. All responses under this Sources Sought shall be sent to Chad Manson via email at chad.d.manson@usace.army.mil and Anelis Nazario Castillo via email anelis.i.nazario-castillo@usace.army.mil. This is a market survey and notification of intent only. This is not a request to respond to a solicitation. A determination by the Government to compete this proposed contract based upon responses to this notice is solely within the direction of the Government.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/e945a2a32b454a1bad36e6dd864f1bb4/view)
- Place of Performance
- Address: FL 33493, USA
- Zip Code: 33493
- Country: USA
- Zip Code: 33493
- Record
- SN07398629-F 20250406/250404230054 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |