Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF APRIL 03, 2025 SAM #8529
SOLICITATION NOTICE

65 -- Bariatric Exam Tables Grand Junction VA Medical Center, CO

Notice Date
4/1/2025 8:05:35 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
NETWORK CONTRACT OFFICE 19 (36C259) Greenwood Village CO 80111 USA
 
ZIP Code
80111
 
Solicitation Number
36C25925Q0332
 
Response Due
4/4/2025 11:00:00 AM
 
Archive Date
05/04/2025
 
Point of Contact
Stephanie Cahill, Contract Specialist, Phone: 303-712-5841
 
E-Mail Address
Stephanie.Cahill@va.gov
(Stephanie.Cahill@va.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Awardee
null
 
Description
As of April 1st, 2025: the salient characteristic for weight capacity is hereby updated from 700 lbs to 650 lbs. Exam tables must be able to support up to 650 lbs. Salient Characteristics: Exam table must be ADA compliant for a small exam room. (Exam rooms are approximately 10 x 10 and usually includes an exam bed, provider desk, and clinical work area.) Table dimensions: **+/- 2 inches from the provided dimension is acceptable** Table length expandable from 57 to 78 approximate when flat Table width approx.. 28 Bed/exam table base should be approximately 46 length by 32 wide Must include seamless upholstered/cushioned exam table tops width approximately 28 Upholstery must be seamless, non-porous, and offer a protective finish to resist bacteria growth, staining, and damage. Preferred color of upholstery: black Must include leg extensions can extend 18 for patient in prone position Table adjustments: Must be able to adjust height from approx.. 18 (minimum) to approx.. 37 (maximum) **+/- 2 inches acceptable** Table must be able to change from low flat position to up right sitting position and back support positioning with powered control Back support angle: 0 degrees minimum and approx.. 80 degrees maximum Pelvic tilt: 0 degree (horizontal) to 6 degree (up) approximate Must include foot control for powered positioning (height adjustment, back, tilt and angle adjustments) Base unit must include at least one (1) storage drawer Approximately 9 x 19 x 4 to store a small amount of clinical supplies Must be heated for OB/GYN or Urology use Weight capacity: must be able to support up to 700 lbs. 650 lbs. Must include side safety handles (2 per table) that can lock into place to prevent left or right rotation. Should be able to rotate to the side or toward the back of the table for improved access and stability of the patient Must include stirrups Must be able to use with electrical outlets (plug with grounding pin) Power requirements: 115-230 V depending on configuration Safety features: Cutoff sensor activates when obstruction is in the moving tracks Safety switch on side of table to manually stop movement
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/971ea1b0545640a7b79b4bd8367effe0/view)
 
Place of Performance
Address: Grand Junction VA Medical Center 2121 North Ave., Grand Junction 81501, USA
Zip Code: 81501
Country: USA
 
Record
SN07393897-F 20250403/250401230054 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.