SOURCES SOUGHT
65 -- Automatic External Defibrillator
- Notice Date
- 2/25/2025 12:27:43 PM
- Notice Type
- Sources Sought
- NAICS
- 811210
—
- Contracting Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
- ZIP Code
- 23667
- Solicitation Number
- 36C24625Q0466
- Response Due
- 2/26/2025 1:00:00 PM
- Archive Date
- 03/28/2025
- Point of Contact
- Byron Brown, Contracting Officer, Phone: None
- E-Mail Address
-
Byron.Brown4@va.gov
(Byron.Brown4@va.gov)
- Awardee
- null
- Description
- IN The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Wake VA outpatient clinic is conducting Market Research through this sources sought notice to help determine the availability of qualified Businesses, capable of providing Automatic external defibrillator that meets, but not limited to, the following: Automatic external defibrillator Utilizes a single pair of disposable electrodes to monitor the ECG and deliver the defibrillator discharge Evaluates electrode connection and patient ECG to determine if defibrillation is required. Shockable Rhythms: Ventricular Fibrillation with average amplitude > 100 microvolts Complex ventricular tachycardia with rates greater than 150 BPM for adults, 200 BPM for pediatrics Electrically isolated patient connections Patient Impedance measurement range: 0 to 300 ohms User Replaceable Battery Configurable automatic self-test Semi-automatic and fully automatic defibrillation protocol LCD Display Battery health / self test indicator Rectilinear Biphasic Wave form Charge time <10 sec Charge Hold Time: 30 seconds CPR: Metronome Rate Variable; 60 to 100CPM Must include Battery, Carrying case 9-inch Standard Wall Cabinet -approximate dimensions 17,5"" W x 9"" D x 17.5""H Approximate Exterior Dimensions (D x W x H): 11.5"" x 9.5"" x 5.25"" Portable defibrillator-monitor-recorder. Integral unit system operable from self-contained rechargeable batteries. ECG may be viewed through paddles or patient cable. Color LCD Display Guidelines 2020- compatible AED w/ manual override Code Readiness testing system High current biphasic waveform from rectilinear biphasic 3 lead ECG cable with AHA markings Advisory Defibrillation Built-in test port, compact flash card slot Integrated AC Power (120 VAC/60 Hz) Rechargeable lithium ion battery Numeric display of CPR Depth and Rate for Adult and Pediatric patients Visual and audio prompts to coach CPR depth (Adult patient only) Release bar to ensure adequate release off the chest Metronome to coach rate for Adult and Pediatric patients Adult and Pediatric AED ECG analysis (analyze mode) See-Thru CPR filter WiFi Capable Cable manager Defib Mentor familiarization aid Thermal Recorder Pacing includes: Pacing Cable (also supports CPR) ECG leads Masimo Pulse Oximetry Signal Extraction Technology Reusable adult sensor & reusable 4 ft ext. cable NIBP includes: 23-33cm reusable cuff & 3 meter air hose, RMT motion tolerance, for use with adult, pedi and neonatal patients ETCO2 includes: CO2 Sensor, For use with adult, pedi, and neonatal patients Approximate Exterior Dimensions (D x W x H): 13"" x 11"" x 8.5"" Inches All respondents shall indicate/provide the following: Whether or not they are small business manufacturers of the products they wish to offer, or if they are a reseller of a small business manufacturer. A copy of its capabilities statement. Failure to provide the above information may result in the potential offeror being considered incapable of meeting the VA s needs. If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor/licenser of their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered capable of meeting the VA s needs. The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research, and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses.� All responses shall be submitted in writing no later than February 26, at 4pmPM EST to the attention of:� Byron.Brown4@va.gov Please title the subject line for all responses as: Automatic External Defibrillator
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/97f21ab4ddea423aba1863aa3a198aa7/view)
- Place of Performance
- Address: Wake Country VA outpatient Clinic 2700 Benson Road, Garner 27529
- Zip Code: 27529
- Zip Code: 27529
- Record
- SN07353476-F 20250227/250225230041 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |