Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 27, 2025 SAM #8493
SOLICITATION NOTICE

J -- Underground Cabling Plant Maintenance, Location Service, and Building Cable Additions at the U.S. Department of State, Diplomatic Security Service, Foreign Affairs Security Training Center (FASTC)

Notice Date
2/25/2025 2:51:12 PM
 
Notice Type
Solicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
ACQUISITIONS - AQM MOMENTUM WASHINGTON DC 20520 USA
 
ZIP Code
20520
 
Solicitation Number
AQ106924A3517
 
Response Due
2/28/2025 2:00:00 PM
 
Archive Date
03/15/2025
 
Point of Contact
Patrick Jones, BJ Roper
 
E-Mail Address
jonespr@state.gov, roperjrma@state.gov
(jonespr@state.gov, roperjrma@state.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
Summary of the Statement of Work (SOW) for Underground Cabling Plant Maintenance Purpose: The U.S. Department of State requires a contract for emergency underground cable repairs at the Foreign Affairs Security Training Center (FASTC) for a base year and four optional renewal years. The scope includes maintenance of approximately 400 miles of underground cabling and additional interior cabling for data drops in existing buildings. THIS IS A TOTAL SMALL BUSINESS SET ASIDE Scope of Work:Emergency Repairs: Address failures in underground cabling systems due to natural or manmade events, requiring expedited response. Cabling Installation: Install additional data drops in existing buildings based on detailed requirements provided in specific Statements of Work. Performance Period: The contract spans one base year with four optional years, contingent upon funding availability. Government Furnished Materials: The government will supply necessary documentation and specifications for the contractor. Reporting Requirements: Contractors must provide daily updates on emergency repairs and submit documentation of completed work, including cable test results. Quality Assurance: Compliance with applicable standards is mandatory, with the government reserving inspection rights. Key Provisions: 1. Adherence to Virginia State Law regarding underground work. 2. Timely response to emergency situations, with repairs initiated within 24 hours. 3. Restoration of work areas to original conditions post-repair. 4. Itemized billing for completed work. Location Services: Contractors must mark underground cable pathways within two business days of notification. Building Cabling Standards: Clear guidelines for cabling installation, including cable types, installation methods, testing protocols, and labeling standards. Warranty: Workmanship guaranteed for six months post-acceptance. Labor Security Requirements: Contractor personnel must be U.S. citizens or legal aliens with background checks. Invoice Submission: Invoices to be submitted quarterly via the Invoice Processing Platform (IPP). *The order that comes from this solicitation will be awarded to the Lowest Price Technically Acceptable (LPTA). The areas that will be reviewed as Acceptable/Unaccaptable are as follows: Criteria 1: Does vendor have experience with Duct bank and underground repairs? Criteria 2: Does vendor have experience with Installing CAT6/Fiber cable? Criteria 3: Does vendor have experience with connecting cabling to racks and patch panels? Criteria 4: Does Vendor have experience with terminating cabling, different types of terminations such as LC/SC, RJ-45, keystone, and wall ports? Criteria 5: Does vendor have experience in heavy digging machinery as it pertains to duct bank repair/construction? Criteria 6: Does vendor have experience and means to pull fiber through duct banks? Criteria 7: Does vendor have experience/means to install conduit for cabling? Criteria 8: Does vendor have employees that can be issued a State Dept FAC badge, employees that can pass a moderate risk public trust background check? Criteria 9: Does vendor have ability to mark underground duct banks? Criteria 10: Does vendor have experience in pumping water and debris from manholes? Criteria 11: Does the vendor have equipment to pump out water and debris from manholes? Criteria 12: Does vendor agree to respond to emergency repair request by phone within 4 hours of receiving notification by phone? Criteria 13: Does vendor agree to be on site within 24 hours of initial notification of emergency repairs? Criteria 14: Does vendor agree respond to non-emergency request for quote/statement of work within 5 business days? Criteria 15: Does vendor agree to using the color code standard set for FASTC networks? Any questions must be submitted in email by February 25, 2025 5pm EST to BJ Roper (roperjrma@state.gov) and Patrick Jones (jonespr@state.gov).
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/728dcebf6a5a48adbe206e4115168258/view)
 
Place of Performance
Address: Blackstone, VA 23824, USA
Zip Code: 23824
Country: USA
 
Record
SN07352511-F 20250227/250225230033 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.