SOLICITATION NOTICE
65 -- GULDMAN CEILING LIFT/NURSING SVC
- Notice Date
- 9/1/2022 10:31:23 AM
- Notice Type
- Presolicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262) Gilbert AZ 85297 USA
- ZIP Code
- 85297
- Solicitation Number
- 36C26222Q1652
- Response Due
- 9/6/2022 9:00:00 AM
- Archive Date
- 10/06/2022
- Point of Contact
- April Graves, April Graves, Phone: 602-795-4475
- E-Mail Address
-
April.Graves@va.gov
(April.Graves@va.gov)
- Awardee
- null
- Description
- The San Diego VA Medical Center hemodialysis clinic is requesting installation of a new patient lift system. The hemodialysis clinic has an installed lift system that needs to be removed and replaced with a new system that meets the needs of the patients and caregivers. Brand name or equal. The new patient lift system must be compatible with existing Guldmann installation and not require any new construction. The system should be a ceiling lift system manufactured by Guldmann Inc. for compatibility, utilizing GH3+ ceiling lift motors with class III digital medical scales built into each motor assembly. The vendor must be capable of disconnecting and removing the existing lift system, without requiring any new construction, or interfering with normal day-to-day operations. The new system must be capable of being installed on existing mounting points, without requiring any new construction, or interfering with normal day-to-day operations. The new lift system, including all rails, lifts and mounting hardware shall be designed and manufactured by a single entity, as a unified system, to ensure all components work together. Specifications of new system: The system must be a medical lift system, with 7 independent motor/hoist assemblies, each certified to lift at least 550Lb at each location. The system shall serve the entire 20-bed dialysis clinic located on the third floor west of the VA San Diego Medical Center located at 3350 La Jolla Village Drive, San Diego, Ca 92161. The power input requirement of the system shall be single phase, 115-120 volts. The system design must be an XY gantry ceiling lift, so that the motor/hoist assembly can be moved forward, back, and side to side. The system must offer in-rail charging, so that the motor/hoist assembly is continually charged, no matter where it is positioned on the rail. No charging docks shall be used. Each motor/hoist assembly will offer and emergency stop, and emergency lowering function. These functions must be easily accessible by means of a hanging strap or lanyard. Due to height constraints of the existing location, each lift unit must have a calibrated, high precision Class III scale built into the motor/hoist assembly, and not have a separate scale which hangs down separately from the motor motor/hoist assembly. When raised to the maximum height, the bottom of the lift hanger should not be below 80 inches from the finished floor. Integrated Class III scale must be designed to accurately monitor patient weight changes in the lift sling, for example in the hemodialysis setting, where the patient is weighed both before and after treatment. The Integrated Class III scale must display weight in kilograms. The Integrated Class III scale must be able to be calibrated on-site. The scale must have a pendant, or remote control which hangs down from the motor/hoist assembly and allows caregivers to easily control the lift position, and activate the Class III scale. The patient weight must be displayed on the pendant, so that caregivers can easily read the values displayed.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/ffbddde13ff7407ca838bc5c26328ecd/view)
- Place of Performance
- Address: VA Medical Center San Diego 3350 La Jolla Village Dr, San Diego 32161, USA
- Zip Code: 32161
- Country: USA
- Zip Code: 32161
- Record
- SN06450963-F 20220903/220901230127 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |