SOURCES SOUGHT
34 -- Welding Booths
- Notice Date
- 5/26/2020 6:28:21 AM
- Notice Type
- Sources Sought
- NAICS
- 333992
— Welding and Soldering Equipment Manufacturing
- Contracting Office
- NORFOLK NAVAL SHIPYARD GF PORTSMOUTH VA 23709-5000 USA
- ZIP Code
- 23709-5000
- Solicitation Number
- N4215820RC00773
- Response Due
- 6/5/2020 9:00:00 AM
- Archive Date
- 06/20/2020
- Point of Contact
- Kayla V Modic, Phone: 7573961938
- E-Mail Address
-
kayla.modic@navy.mil
(kayla.modic@navy.mil)
- Description
- Installation: The system shall include all components, parts, and features necessary to meet the performance requirements specified herein. (2) Dust collectors consisting of the following: Collector Body Heavy Duty Construction: Fully welded 10 & 12-gauge steel. Dimensions of Unit: 174.25� (W) x 105� (D) x 105� (T) Weight Range: 9,900-12,300 pounds. Motor/Blower: Three (3) 40HP, direct drive �C� face mounted blower wheels, 22� @ 88% Air Flow: �37,000 CFM @ 11.5� external static pressure Silencing: Internal noise abatement in motor/blower compartment to dampen noise (70-85dB at 5�). Dust collector consisting of the following: Collector Body Heavy Duty Construction: Fully welded 10 & 12-gauge steel. Dimensions of Unit: 88� (W) x 105� (D) x 166.14� (T) Weight Range: 4,800-6,400 pounds. Motor/Blower: Two (2) 25HP, direct drive �C� face mounted blower wheels, 22� @ 55% Air Flow: �16,000 CFM @ 11.5� external static pressure Internal and External finishes shall be powder coated Silencing: Internal noise abatement in motor/blower compartment to dampen noise (70-85dB at 5�). Dust collector consisting of the following: Collector Body Heavy Duty Construction: Fully welded 10 & 12-gauge steel. Dimensions of Unit: 116.5� (W) x 105� (D) x 166.5� (T) Weight Range: 6,600-8,200 pounds. Motor/Blower: Two (2) 40HP, direct drive �C� face mounted blower wheels, 22� 88% Air Flow: �16,000 CFM @ 11.5� external static pressure Internal and External finishes shall be powder coated Silencing: Internal noise abatement in motor/blower compartment to dampen noise (70-85dB at 5�). Stand hopper and collection drums: three (3) 72� stands with three (3) hoppers and three (3) collection drums. Compressed Air Requirements: 1� NPT air connection; 70-100 PSI of dry, oil free air required. ������������ ������������ Electrical Requirements: ������������ Three Phase, 460 Volt 60 HZ Motor starter, controller, ON/OFF switch, pressure gauge, ������������ Integrated disconnect switch, and overload in a NEMA 12 electrical enclosure. ������������ VFD: Variable frequency drive for soft start. ������������ Filter Cartridges: ������������ Pulsed Air filter cleaning system. ������������ Nano flame retardant media (MERV 15) ������������ HEPA Filter Module Rated between 20,000-25,000 CFM. Arc Gouge booth construction: Dimensions: 92� x 144� Walls and roof framing shall be 2� x 2� x 1/8� welded square tubing, Outer walls will be covered with 16 Ga. steel sheet, and roof panels shall be 18ga. Steel sheet, all seams shall be covered, entire booth shall be primed and painted. Exterior walls shall be insulated with 2� of mineral wool; interior walls shall be covered with 3/16� steel plate. Interior walls shall have an exhaust opening consisting of six (6) slots 2.5� x 84�; with six (6) additional 4.5� x 92�, x 3/16 flat bars attach to reduce spark entrance to the exhaust plenum. Roof shall have two (2) 36� X 20� openings with a 2� flange to connect the exhaust ducting. Installation: Contractor shall be responsible for all equipment and qualified personnel required for installation. � Mechanical Installation. The Contractor shall provide all labor, ductwork, fume arms, overhead hoods, manual slide gates, spark coolers, support stands, interconnecting hoses, and any other materials to make ready to operate all equipment required by this contract. All material, components shall be installed to original manufacturer's tolerances. � Electrical Installation: The Contractor shall provide all labor, wiring, cables, disconnects, connectors, and any other materials for complete installation of any requisite electrical equipment. Installation shall include necessary power, control, and interconnecting wiring installed in conduit.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/a3613335cf5c45a39bc3caa50d05a972/view)
- Place of Performance
- Address: Portsmouth, VA 23709, USA
- Zip Code: 23709
- Country: USA
- Zip Code: 23709
- Record
- SN05670810-F 20200528/200526230151 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |