DOCUMENT
Q -- VS120 5-Slide Scanner, AutoLoader, Software, Fluorescence - Attachment
- Notice Date
- 2/29/2012
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;VA Boston Healthcare System;Contracting Officer (90C);940 Belmont Street;Brockton MA 02301
- ZIP Code
- 02301
- Solicitation Number
- VA24112Q0453
- Response Due
- 3/5/2012
- Archive Date
- 4/4/2012
- Point of Contact
- Stephen J. Flynn
- Small Business Set-Aside
- N/A
- Description
- This is a SOURCES SOUGHT NOTICE / REQUEST FOR INFORMATION; not a pre-solicitation notice or solicitation for proposals/quotations. Pursuant to FAR Part 10 (Market Research), the purpose of this notice is to: (1) determine if sources capable of satisfying the agency's requirements exists, (2) determine if commercial items suitable to meet the agency's needs are available or could be modified to meet the agency's requirements, and (3) determine the commercial practices of company's engaged in providing the needed service or supply. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action. Requirement: This notice is issued by the Department of Veterans Affairs, Boston VA Healthcare System to identify sources capable of providing the following: VISN 1 Contracting is conducting market research on a whole slide imaging system with fluorescence. We are requesting brand name or equal products that compare to the product information and salient characteristics for the VS 120 5- Slide Scanner with Auto Loader, Software, and the VS 120 Fluorescence manufactured by Olympus America Inc... Please see the following product information and salient characteristics below. Product Information/Salient Characteristics The Olympus VS120 Whole Slide Imaging System is a unique product manufactured by Olympus America, Inc. This state-of-the-art system provides high definition digital images of stained tissue slides, which will serve as novel image-based biomarkers that assist early prediction of cancer risk and guide personalized cancer surveillance strategies. Features provided by the Olympus equipment that meet the requirements and needs are: 1.Microscope based scanning system providing enhanced flexibility in scanning techniques. 2.Utilize multiple scanning objectives: 4x, 10x, 20x, 40x 3.Ability to add 60x or 100x oil scanning 4.Ability to scan in multiple Z?planes 5.Able to provide an Extended Focus scan (EFI) 6.The scanning system must allow for the real time review of the high resolution scan during the scanning process 7.Able to scan multiple ROI from one sample 8.Scan multiple magnification layers within the same image file 9.Able to output image files to JP2000,.tiff or.bgt (bigtiff) 10.The scanning system must be capable of fluorescence scanning 11.The scanning system must be able to support both color and monochrome cameras 12.The system must be able to support 16 bit monochrome image files 13.Fluorescence calibration must be available for each individual color channel 14.The system must provide real?time online deblurring for fluorescence scanning applications 15.The system must be able to support advanced image processing software including maximum intensity projection and deconvolution algorithms EQUIPMENT: VS120-SLS VS120 5-SLIDE SCANNER WITH AUTOLOADER AND BASIC SOFTWARE VS-035-4 VS FLUORESCENCE SOFTWARE UPGRDE VERSION 2.4 VS120-FL VS120 FLUORESCENCE (NO SOFTWARE) CDI-INSTALL CDI-INSTALL; CDI INSTALLATION AND TRAINING FEE 1-U2B836 UPLSAPO100XO;UPLAN S-APO 100X OIL OBJ,NA1.40,WDO.12 VS120 FLUORESCENCE SPECIFICATIONS The VS120-SL Scanning System has been specifically designed for high throughput facilities that require fast scanning speed and high image resolution. It is ideal for research laboratories that are faced with a growing number of samples to process. For these laboratories, it is more efficient to scan slides in batches and review them later. The VS120-SL 100 Slide autoloader makes it quick and easy to archive slides and produce permanent records. The careful integration of all the components creates a highly flexible system that enables the user to acquire digital slides quickly and effortlessly. The slides can be scanned at 2x, 10x, 20x or 40x magnification with automated tissue detection and multiple regions of interests. VS120-SL SPECIFICATIONS Intended SpecimenObservable SpecimenGlass slide with cover glass Size of Glass SlideWidth: 26mm(52mm in option), Length:76mm, Thickness:0.9mm-1.2mm Size of Cover GlassThickness: 0.12mm-0.17mm Microscope FrameIlluminatorBuilt-in Koehler illumination for transmitted light Objective Lenses2x, 10x, 20x, 40x with a motorized revolving nosepiece. Optional 60x or 100x oil objectives Optional 60X or 100X oil objectives Motorized StageMotorized XY stage with automatic control FocusingMotorized automatic control Digital CameraCCD Camera2/3" CCD camera, 6.45 ?m x 6.45 ?m pixel size, high sensitivety, high resolution Image CorrectionShading correction, Auto white balance ScanScan AreaW 26mm x H 64 mm (W 52mm x H 64mm as an option) ResolutionBetter than 0.33 micron/pixel when using 20X objective Better than 0.16 micron/pixel when using 40X objective System ControlComputerCompatible with Windows XP Professional, Windows 7 (32/64bit) Network Interface100/1000 Mbit/s Ethernet Memory4 GB RAM Hard Disc Drive500 GB or more DisplayHigh resolution 24" TFT monitor SoftwareImage format: vsi, JPEG, TIF Zooming while scanning Annotations Automatic sample detection Z-stack Extended focus imaging Screen capture Stepless zooming Synchronised multi-images display Automatic stitching Slide loader control Network Software with database function and conference up to 5 user accounts consultation Conference up to 20 user accounts, Conference more than 20 user accounts. EnvironmentPowerAC100-120V/220-240V, 50/60Hz Weight*110Kg55Kg55Kg Operating EnvironmentTemperature: 15-28 degree centigrade Power ConsumptionLess than 900VA VS120 FLUORESCENCE SPECIFICATIONS "Dual cameras support brightfield and fluorescence "14-bit monochrome camera (XM10) "Support of 16-bit grayscale data "Multichannel imaging (> 3 channels) "Dedicated fluorescence acquisition wizard "Virtual-Z scan mode for fluorescence Z-stack acquisition "Optional: advance filtering, deconvolution, max intensity projection Anticipated NAICS Code/Size Standard: The applicable NAICS Code is 339112. Submission of Information: Companies having capabilities necessary to meet or exceed the stated requirements are invited to provide information to contribute to this market survey/sources sought notice including commercial market information and company information. Companies may respond to this Sources Sought Notice via e-mail to Stephen.Flynn@va.gov no later than March 5, 2012 at 10:00AM, Eastern Time with the following information/documentation: 1. Name of Company, Address and DUNS Number. 2. Point of Contact and Phone Number. 3. Business Size applicable to the NAICS Code: 8(a) Business / HUBZone Small Business / Service-Disabled Veteran-Owned Small Business / Small Business / Large Business 4. Commercial market information and practices applicable to this supply. 5. A positive statement of intent to submit a quote as a prime contractor if a solicitation is issued as a result of this Sources Sought Notice. 6. Detail information regarding product with specifications. [Include brochures and reference materials] CCR: Interested parties should register in the Central Contractor Registration (CCR). The CCR can be obtained by accessing the internet at www.ccr.gov. Disclaimer and Important Notes: This Sources Sought Notice is for market research purposes only and does not constitute a Request for Proposal/Quotation; and, it is not considered to be a commitment by the Government to award a contract nor will the Government pay for any information provided; no basis for claim against the Government shall arise as a result from a response to this Sources Sought Notice or Government use of any information provided. Failure to submit information in sufficient detail may result in considering a company as not a viable source and may influence competition and set-aside decisions. Regardless of the information obtained from this Sources Sought Notice, the Government reserves the right to consider any arrangement as deemed appropriated for this requirement. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. No proprietary, classified, confidential, or sensitive information should be included in your response to this Sources Sought Notice. The Government reserves the right to use any information provided by respondents for any purpose deemed necessary and legally appropriate, including using technical information provided by respondents in any resultant solicitation. At this time no solicitation exists; therefore, do not request a copy of the Solicitation. After a review of the responses received, a pre-solicitation notice and solicitation may be published on Federal Business Opportunities (FedBizOpps) website. It is the potential offeror's responsibility to monitor FedBizOpps for release of any future solicitation that may result from this Sources Sought Notice. However, responses to this Sources Sought Notice will not be considered adequate responses to any resultant solicitation.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BoVAMC/VAMCCO80220/VA24112Q0453/listing.html)
- Document(s)
- Attachment
- File Name: VA241-12-Q-0453 VA241-12-Q-0453.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=302232&FileName=VA241-12-Q-0453-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=302232&FileName=VA241-12-Q-0453-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA241-12-Q-0453 VA241-12-Q-0453.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=302232&FileName=VA241-12-Q-0453-000.docx)
- Place of Performance
- Address: Department of Veterans Affairs;Jamaica Plain VAMC;150 South Huntington Ave.;Boston, Ma.
- Zip Code: 02130-4817
- Zip Code: 02130-4817
- Record
- SN02685545-W 20120302/120229234612-78724170d70ff15a953e2ec435c1ecb1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |